Dryer won't stop

01 - Air Flow Problem
If the vent is clogged or partially clogged, it will restrict the airflow through the dryer, substantially increasing the drying time. To ensure proper dryer performance, you should clean your dryer’s venting system at least once per year.
02 - Dryer Blower Wheel
The blower wheel draws air through the dryer and pushes the air out the vent. Clumps of lint, socks, and small articles of clothing can escape the lint filter and get caught in the blower wheel. In addition, the blower wheel sleeve can wear out, allowing the blower wheel to wobble on the motor shaft. If the blower wheel is obstructed or defective, it may take too long to dry clothes. To determine if the blower wheel is working properly, remove the dryer vent and assess the strength of the air fl...ow. If the air flow is weak, check the blower wheel for obstructions. If no obstructions are present, try rotating the blower wheel by hand. If the blower wheel wobbles as it turns, replace it.
Required Part
Dryer Blower Wheel
Enter model number to search for the required part specific to your product
Most Common Solution
03 - Incoming Power Problem
Plug in the dryer or check house power at outlet/circuit breaker.
04 - Dryer Control Board
A dryer's control board controls the voltage being sent to all of the appliance's electrical components. If there's no obstruction in the dryer's venting and the dryer is heating to the proper temperature, it's possible the control board is defective and allowing the appliance to run longer than it should. You can inspect the board for signs of damage or a shorted component. You can also use a multimeter to test for voltage reaching the drive motor after reviewing the dryer's wiring diagram.
Required Part
Dryer Control Board
Enter model number to search for the required part specific to your product
Common Solution
05 - Dryer Main Control Board
A dryer's main control board controls the voltage being sent to all of the appliance's electrical components. If there's no obstruction in the dryer's venting and the dryer is heating to the proper temperature, it's possible the control board is defective and allowing the appliance to run longer than it should. You can inspect the board for signs of damage or a shorted component.
Required Part
Dryer Main Control Board
Enter model number to search for the required part specific to your product
Common Solution
06 - Dirty Moisture Sensor Bars
The control board uses the moisture sensor bars to sense the dampness of the clothes. Over time the sensor bars can become coated, expecially from dryer sheet residue. Try cleaning off the bars with warm soap and water. If the sensor bars are damaged they will need to be replaced.